Datasheet
2 | SP3
tel: 800.423.5483 • +1.818.701.2750 • fax: +1.818.701.2799
now part of Measurement Specialties, Inc.
Ø .125 [3,18] thru
(Ø 2.30 [58,4] B.C. 90º apart)
1.10 [27,9]2.00 [50,8] max.
0.69 [17,5]
1.63 [41,4]
1.63 [41,4]
1.90 [48,3]
Ø .53 [13,5]
.165 [4,2]
0.61 [15,5]
2.50 [63,5]
1.56 [39,6]
Electrical Cable, 24 GA, 3-conductor,
shielded, 40 in. [1 meter] long
0.24 [6,1]
DIMENSIONS ARE IN INCHES [MM]
tolerances are 0.04 IN. [1,0 MM] unless otherwise noted.
* tolerance = +.005 –.001 [+0,1 –0,0]
** tolerance = +.005 –.005 [+0,1 –0,1]
see detail
eyelet detail
.165
[4,19]**
Ø.191 [4,19]*
Ø.375 [9,52]**
Electrical Connection:
Outline Drawing (w/o bracket):
4..20 mA 0..10 Vdc
0...10 Vdc 4...20 mA
12...32 Vdc 8...40 Vdc
(red)
0...10 Vdc n/c
(grn)
common 4...20 mA
(blk)
red
red
green
green (n/c)
black
black
8–40 Vdc
–
+
12–32 Vdc
+
–
4–20 mA
return
0–10 Vdc
common
4..20 mA
0..10 Vdc
RED: 8–40 Vdc In
BLK: 4–20 mA Out
RED: 12–32 Vdc In
GRN: 0–10 Vdc Out
BLK: common
red black
8–40 Vdc
–
+
4–20 mA
return
12–32 Vdc
0–10 Vdc
common
red
black
green
–
+
celesco.com • info@celesco.com