Product specifications

- 6 -
Product Specifications
The CellarMate is designed to operate at or above its rated capacities for total BTUH and CFM under
recommended conditions.
Model Number 025 050 088 200
Performance
Nominal Tonnage Ton 1/4 1/2 1 2
Nominal Compressor HP 1/3 1/2 1 2.5
Net Cooling capacity*
@ 70 DEG F Ambient BTUH 3300/3650 5600/6050 8400/9100 16200/17750
@ 80 DEG F Ambient BTUH 3000/3300 5300/5700 7800/8450 15200/16550
@ 90 DEG F Ambient BTUH 2800/3050 4850/5275 7300/7900 14100/15350
Controls
Type Room mounted non-programmable thermostat
Accuracy ± 2°F
Evaporator Section
Fan motor Size Watts 75 100 195 240
Rated air flow CFM 235 430 510 740
Air flow with 25' flex duct CFM 207 400 485 715
Condenser Section
Fan motor Size Watts 75 100 195 240
Rated air flow CFM 253 400 500 750
Air flow with 25' flex duct CFM 220 365 475 720
Electrical Requirements
Power requirements V/P/H 115/1/60 115/1/60 230/1/60 230/1/60
Current Draw - Cooling mode Amps 8.6 11.9 9 16
minimum Circuit Size Amps 15 15 15 20
Typical Testing Data (Factory)
Head pressure psig 159 140 140 138
Suction Pressure psig 40 30 25 27
Condenser Inlet Temperature Deg F 81 74 79 78
Condenser Outlet Temperature Deg F 98 98 99 107
Evaporator Inlet Temperature Deg F 56 55 57 55
Evaporator Outlet Temperature Deg F 44 44 43 46
Agency Approval
ETL - Conforms to UL Std. 1995
*1. Net cooling capacity @ cellar temperature & humidity of 55°F & 60% RH / 60°F & 60% RH and at rated airflow. Reduce capacity by
3% for each 10% reduction in either condenser or evaporator airflow, 5% for both.
2. Cellarmate reserves the right to make changes to this document without prior notice at its sole discretion.
3. All ratings @ sea level.