Specifications

CellarMate Manual Page 32
Cellar Temperature is Too High, but Supply Air is Cold
Possible Cause Solution
Not enough evaporator air
flow
Remove blockage in supply or return ductwork
Check and clean filter and coil
Coil frozen—shut-off unit for two hours
Cellar loads are too high Install additional insulation
Replace with larger unit
Cellar Humidity
Humidity Too Low or Supply Air is Too Cold, Without Optional Humidifier
Possible Cause Solution
Not enough evaporator air
flow
Remove blockage in supply or return ductwork
Check and clean filter and coil
Coil frozen—shut-off unit for two hours
Defective Thermal Expansion
Valve
If under warranty, call for service
If not under warranty, call a refrigeration
technician
Humidity Too Low Without Optional Humidifier
Possible Cause Solution
No moisture being added to
cellar
Add CellarMate humidifier or a room humidifier
Defective Thermal Expansion
Valve
If under warranty, call for service
If not under warranty, call a refrigeration
technician