User's Manual
Table Of Contents
- CONTENTS
- FIGURES
- TABLES
- INTRODUCTION
- INSTALLATION GUIDE
- Applicable Documents
- Scope
- Important Safety Precautions
- ICU Operation Instructions
- Array Installation
- Assembly Instructions for the PCS 1x4x4 Array
- PCS 1x8x8 Array Assembly Instructions
- BEAMER® System Setup
- BEAMER® System Sector Array Installation Record
- Test Procedure for Measuring the Rx Gain Balance
- Smart-Terminal Program Description
- BSM (BEAMER® SYSTEM MANAGER) PROGRAM
- Functions
- Requirements for Operation
- User Interface Description
- Status Reports
- BSM S/W
- BSM Main Screen
- Comm Port Selection
- Password Entering
- Host Selection
- Installation of ICU in System
- Failure Conditions Selection
- BEAMER® Limits Definition
- Shut Down Conditions Enable/Disable
- ICU Limits Definition
- System Definition
- Sub-Array and BEAMER® Setting
- Sub Array Setting
- BEAMER® Installation
- Column and Row Definition
- Sub-Array Status and Attenuator Setting
- Control & BEAMER® Setting
- BEAMER® Control
- ICU Status
- ICU CTRLR Status
- ICU Properties
- SOFTWARE DOWNLOAD GUIDE
- WARRANTY
- Exclusions
- Warranty Limitations
- INDEX
INSTALLATION GUIDE
Confidential, Proprietary Information
Title: PolBEAMER PCS (3.2) Array System-
Assembly and Operation Manual
Doc. No.:
913000801
Rev.: 01
Page: 52 of 91
The receivers gain is set. You can perform gain tests, using one of the above-suggested procedures.
2.9. BEAMER® System Sector Array Installation Record
Sector # ...............................................
ICU address.........................................
ICU ID number ................................... (from unit label)
Array Number .....................................
2.9.1. Installed BEAMER® Modules
Unit#1 ID(from unit label).................. system address
Unit#2 ID (from unit label)................. system address
Unit#3 ID (from unit label)................. system address
Unit#4 ID (from unit label)................. system address
2.9.2. RF Cable Loss
Tx........................................................ dB
Rx1...................................................... dB
Rx2...................................................... dB
2.9.3. Tx Channel
BTS output power level ...................... dBm (at sector maximum capacity)
Tx-ABT gain....................................... dB
BEAMER® measured output power:
P1 ........................................................ dBm
P2 ........................................................ dBm
P3 ........................................................ dBm
P4 ........................................................ dBm
Average............................................... dBm
2.9.4. Rx Channels
Estimated ABT-Rx gain
Rx1...................................................... dB
Rx2...................................................... dB