4.4.7.1. Enter Password
Clicking on the Enter password function will display the following window:
The displayed window enables entering the required password, which enables the loading process.
4.4.7.2. Low Level
Clicking on Low Level sets the Guest level authorization.
4.4.7.3. Change Password
This function is enabled when the Administrator authorization is enabled and enables changing the
password for authorization.
4.5. Program Loading Procedure
4.5.1. Procedure for Loading Program to the ICU
To load a new version of application program file to the ICU controller, follow the following
instructions:
1. Connect the PC that includes the Celletra program loader program to the ICU via the serial
port.
2. If you wish to keep the log file then save it, otherwise the log file will be erased during the new
file loading.
3. Operate Celletra program loader program and wait until the address of the ICU appears at the
ICU address bar. If the system includes few ICUs, select the address of the required ICU from
the address bar.
4. From the Setting menu select Comport and select the required communication path to the ICU.
If the PC is connected via the serial port of the PC then check the RS-232 and define the COMM
port in the PC that is used.
If the PC is connected via the a telephone line by a modem, then check the MODEM and dial the
telephone number of the destination modem.
5. From the Setting menu, click on Destination and select ICU as the destination for loading. The
following warning message will appear to warn that the log file will be erased: