User Manual

Confidential, Proprietary Information
Title: PCS FlexBeamer
®
RF Repeater
System A &O Manual
Doc. No.:
913002500
Rev.: 00
Page: 21 of
80NUMPAGES
1.5.3. BEAMER
®
Monitoring and Control
Monitoring and control (M&C) of the whole RF Repeater is performed from the RAC
by the internal Control Card. The Control card of the RAC has several internal
communication channels and some external channels.
Internal Communication Channels:
FSK modulated signal to control the Beamer FLEXBEAMER® or BAU Beamer
units.
Parallel TTL Level lines to control the ABTs of the RAC.
External Communication Channels:
RS485 through an external connector to BSM operated Local PC
RS232 through the Wireless Modem to the CDMA network and remote BSM
operated PC.
The M&C system will monitor and control the following functions, when the Failure
definitions are fully programmable via MMI and NMS.:
C&M functions for the BEAMER
®
module in FLEXBEAMER® or BAU via
FSK channel includes continuous detection of each BEAMER module status
and Query of selected BEAMER
®
module selected parameters . These
include:
Ø For the P.A half of the BEAMER
®
module:
Input power measurement -
Output Power measurement
Temperature measurement
Tx current consumption
Tx return power alarm
Input voltage
Tx gain control
Tx Phase control
Automatic shut down
Ø For the LNA half of the BEAMER
®
module:
Rx current consumption
Rx gain control.