2.2.2. System Measurement and Testing Conditions
Live +24VDC with high current capability exists on the FLEXBEAMER® and BAU Coaxial
connections of the RAC. (These are the Tx ABT output and the Rx ABT input N-type
connectors at the RAC). Disconnect the AC or DC power to the RAC before any cable is
disconnected from the RAC, FLEXBEAMER® or BAU.
Always use a DC block device connected to the measuring equipment input or output ports
(spectrum analyzer, power meter, or RF signal source), when measuring RAC performance.
Do not apply more than +10dBm of RF input power to any RF port of the
FLEXBEAMER® Repeater system, or irreversible damage may occur.
When measuring high power outputs, always verify that the equipment input port is capable for
handling the expected output power.
When testing the units in lab or during field installation, always practice RF
radiation safety rules. It is not recommended for service or lab personnel to work
closer then 2 meters away from the FLEXBEAMER® Antenna surface when
operated at full RF power.
During lab tests, with AC voltage applied to the RAC, do not use any PCS mobile transmitter
in a range of less than 10 meters from the FLEXBEAMER® unit. An unexpectedly high RF
power might appear at the output ports, which might in turn damage the measuring equipment
connected to that port.