User Manual

Confidential, Proprietary Information
Title: PCS FlexBeamer
®
RF Repeater
System A &O Manual
Doc. No.:
913002500
Rev.: 00
Page: 34 of
80NUMPAGES
Before setting up the system, avoid connecting RF cables between the RAC BAU and the
FLEXBEAMER®. Since the Tx and Rx gain are not calibrated yet, this is done to protect the BAU
and FLEXBEAMER® from overdrive conditions.
The following table can be used as a reference for the RAC and FLEXBEAMER® setting. The table
specifies the pre-set default values.
Note: Many values are not pre-set. The following sections will instruct you
how to set these values, tailored to the specific on-site installation.
Caution: some values ( such as RS-232/RS-485 switch ,Time out and codes
are factory set and should not be changed on site. In particular, these
values relate to the FLEXBEAMER® calibration and operation modes.
Modification of these values, without coordination and specific
authorization from Celletra engineering, can cause invalid
FLEXBEAMER® performance and should be avoided. The changes are
possible by the highest password authorization only.
Parameter Required for RAC
Operation Mode Auto (manufacturer pre defined).
Control Mode Main, Local
RAC configuration
(jumper positions)
(manufacturer pre
defined).
1. Operation “ON”
2. I/O not installed “OFF”
3. MODEM installed(option depend)
“ON”
4. RS-232/RS485 enabled “ON”
System Features # of arrays – 03
Main-1
Diversity-2
BAU-3
arrays type BEAMER
®
Tx/Rx
PCS3.2
The BAU is PCS3.2M
Time out Do not change. Cannot be accessed in
operation mode.
Real time clock Set to location time zone
BEAMER
®
failure
conditions
See Table No. 5
Shut-down conditions All ON.
Table 2: RAC - BEAMER
®
default values and quick reference