User Manual

Confidential, Proprietary Information
Title: PCS FlexBeamer
®
RF Repeater
System A &O Manual
Doc. No.:
913002500
Rev.: 00
Page: 36 of
80NUMPAGES
3.1.5. Coaxial Cables Connection
Ø Connect the Four coaxial cables connecting the RAC and the FLEXBEAMER®. Use
cables with N-Type connected for that purpose.
Ø Be aware to connect the Tx marked connector on the RAC to the Tx Marked
connector on the FLEXBEAMER®. The same is true for the Rx marked cables.
Ø Be aware the FLEXBEAMER® and the RAC might have already other connectors on
the same panel marked “Diversity Tx” or “Diversity Rx”.
3.1.6. FLEXBEAMER® Configuration
3.1.6.1. FLEXBEAMER® Module Registration
The Beamer registration is done by entering to “settings/Array setting/beamer setting and let
the S/W scan all beamer addresses and find the existing Beamers in the system.
After the S/W will find the Beamers hit apply and than go to array address and register the
Beamer in the array by marking an X in Beamer location column.
3.1.6.2. Configuring the Array
After registration the FLEXBEAMER® and BAU in the system you will have a complete
array configuration.
3.1.6.3. BAU configuration
The BAU configuration will be similar to the FLEXBEAMER® configuration.
3.1.7. Setting Limits, Failures and Shut-Down Conditions
3.1.7.1. Setting the BEAMER
®
Limits
Setting the Beamer limits will be done under “Setting/CTRL setting/Beamer limits.
In the following table you will find the recommended numbers.
Note that the limits setting corresponds to the “ Failure Alarms”