Description Meaning
Rx bias T current min 0mA
Rx bias T current max 500mA
3.1.7.3. Setting the BEAMER
®
Shut-Down Conditions
It is recommended to operate all Shut down conditions.
3.1.7.4. Defining System Failure Conditions
Command 'save alarm conditions' (code 26) defines the conditions for failures. These
conditions can be set to the customer's preferences. The following table describes the
command conditions and the suggested failure conditions.
Table 5: Failure conditions
Failure Description Recommended Value
Temperature out of range minor
Input power minor
Output power out of range minor
Tx attenuator no condition
Main Rx attenuator no condition
Div Rx attenuator no condition
BEAMER
®
supply voltage
minor
Tx current major
Main Rx current minor
Div Rx current minor
Return power minor
Power amplifier major
Linearizer N/A for this model
Bias T voltage major
RAC voltage major
Rx bias T current minor
Tx bias T current major
BEAMER
®
CTRLR
minor
RAC CTRLR minor