User Manual

Confidential, Proprietary Information
Title: BEAMER Array System-
Assembly and Operation Manual
Doc. No.: 913002500 Rev.: 00
Page: 67 of 80
5.4. User Interface Description
When operating the program the following window will be displayed:
5.4.1. System Field
The System field displays the address of the RAC and its ID number that is controlled by the operated
program. In case that the system includes few RACs the required RAC can be selected by its address
from the address bar.
When the program is operated it scans the addresses (1 to 4) and displays the address of the existing
RACs in the System filed . In case that no RAC was connected or the RAC was not configured the
address bar will remain blank.
5.4.2. Authorization Field
Authorization field displays the actual authorization level. Two levels of authorization are available:
1. "Guest" level can only observe indications.
2. "Administrator" which enables the application of the loading process and change the passwords
in addition to "Supervisor" abilities.
5.4.3. System Date and Time Field
System date and time function displays the PC’s actual date and time. That time will be registered as
one of the properties of the loaded file.
5.4.4. RAC SW Properties Field
RAC SW properties field is enabled when the loading process is enabled. It displays the properties of
the program file that exists in the RAC. The RAC property information includes the version number and
file loading date and time.
5.4.5. Destination Field
Destination field displays the destination for the file loading – BEAMER or RAC.