User Manual

Confidential, Proprietary Information
Title: BEAMER Array System-
Assembly and Operation Manual
Doc. No.: 913002500 Rev.: 00
Page: 76 of 80
6.2.1. Troubleshooting the system using ICU log file.
6.2.1.1. Getting ICU Log File
For getting the ICU Log File follow the instructions:
1. Select <FILE> option in the main menu.
2. Select <Get Log file> option. A small window, named “Save In” will be displayed.
Set the name of the Log file (or use the default name) and press <save>.
3. A ‘progress window’ will be displayed while reading the data from the ICU.
6.2.1.2. The Log file structure
The log file is a text file with a line of 26 fields
Field No. Field Name Description
1 Failure type
2 Date
3 Time
4 – 20
Beamer Status
(relevant only for Beamer failure)
4 BEAMER address
5 Controller status 0 - OK; other - Fail
6 Temperature Indication checked within Beamer limits
7 Input Power Indication , Checked within Beamer limits
8 Output Power Indication Checked within Beamer limits
9 Tx Attenuator Indication Checked within Beamer limits
10 Main Rx Attenuator Indication, Checked within Beamer limits
11 Div Rx Attenuator Indication Checked within Beamer limits
12 Tx Current Indication Low - 0 Norm - 1 High - 2
13 Main Rx Current Indication Low - 0 Norm - 1 High - 2
14 Div Rx Current Indication Low - 0 Norm - 1 High - 2
15 Return Power Indication 0 - OK;1 - Fail