Owner's manual

cm
Fig.A
Fig.B
I 0184 - 10
GB
- Wheel ALU-S
- Measure the dimensions as shown in the following diagram.
Fig. 9
PRESETTING:
Note: when dE is not set, dE = 0.8 dI is automatic
5.2.3 - SETTING WITH GAUGE EXTENSION ( OPTIONAL C61 )
The extension increases the by 6 cm the gauge distance measurement fi eld (Fig. A) and allows distance
measurement even when the rim has a special profi le (Fig . B).
Proceed as indicated below:
- fi t the extension on the distance gauge
- Measure the distance as already described.
- Read value “a” on the dial and then reset the gauge to “0” and set by hand the value “a + 6”
- Manually set the diameter and the width.
Extension +6
0 Gauge