Owner's manual

I 0184 - 12
GB
5.4.1 - INDICATION OF EXACT CORRECTION POSITION ( C61Z )
In ALU 2, ALU 3 and ALU-S correction mode, it is possible to cancel approximations in the mounting of
the counterweights by proceeding as follows:
Fig. 11
- Press button
- fi t the correction weight in the specifi c seat
- pull out the gauge, bearing in mind that the display shows:
to indicate that the gauge should be pulled further out
to indicate that the gauge should be returned to rest position
The left display gives the indications for reaching the position regarding the inside, while the right display
that of the outside.
- bring the wheel into correct angular position for the side selected.
- move the gauge so that the Led comes ON at the correction plane.
- rotate the gauge so that the correction weight adheres to the rim.
- The fact that the weight application position is no longer vertical (Fig.12) is automatically compensated.
Note : it is not possible to apply automatically the correction weight in position as per Fig. 5/Pos.B;
ALWAYS rotate the gauge into position as per Fig. 5/Pos.A.
Fig. 12