Instruction Manual

I 0709 - 32GB
5.4.5 - STATIC ALWAYS ENABLED
Simultaneous display of the selected correction plane unbalance as well as STATIC unbalance can be enabled/disa
bled. The static frame can always be selected by pressing the
button from the measuring frame.
5.5 - CORRECTION METHOD
One of the three possible correction methods can be selected based on the speci c requirements of the customer.
5.5.1
- STANDARD CORRECTION METHOD
The wheel balancer considers the unbalance within tolerance when the value of each single plane is lower than the
tolerance set.
5.5.2 - EXTERNAL PLANE CORRECTION METHOD
If correcting with adhesive weights, the unbalance is considered within tolerance when the recalculated external
plane weight (clip-on weights) is lower than the tolerance set.
Additional windows appear on the screen always displaying the residual external plane value (clip-on weight):