Manual

19
Use and Maintenance Manual Rev. 11-2010
ENGLISH
Use of the wheel balancing machine
Displays the information screen
Selects unbalance display in g/oz
Displays the threshold
Enables/disables wheel rotation
Splits the unbalance
Displays the second set of buttons
Lift reset with wheel stopped / STOP during spin
6.4 UNBALANCE MEASUREMENT (first set of buttons)
To perform an unbalance measurement spin, close the guard.
After performing a balancing spin, the following are displayed:
The unbalance values.1.
White: wheel locked in correction position / Internal scanning laser positioned on the side.
Light blue: position not reached / Internal scanning laser not positioned.
The red weights that indicate the unbalance position.2.
The weight shadows that indicate where the correction weight should be applied: at the top at 12 o’clock or at the 3.
point indicated by the internal laser.
IF THEWHEEL IN POSITIONSOUND IS ENABLED, A SOUND WILL BE EMITTED WHEN THE CORRECTION POSITION HAS BEEN REACHED.
IF THE UNBALANCE IS LESS THAN THE THRESHOLD VALUE SET, OK IS DISPLAYED INSTEAD OF THE UNBALANCE VALUE TO INDICATE THAT THE
WHEEL IS WITHIN TOLERANCE ON THAT SIDE.
P
RESSING THE BUTTON YOU CAN IN ANY CASE VIEW THE RESIDUAL UNBALANCE.
TO RESUME WITH THE DIMENSIONS OF THE WHEEL MOUNTED, OPEN AND CLOSE THE SPINDLE.
6.4.1 Spindle rotation lock/release
The wheel balancing machine automatically locks spindle rotation if there is an unbalance in the correction position
on one of the sides. To release rotation, press the button
or turn the wheel with force.
If rotation is released and you need to lock it (for example, to facilitate mounting large wheels), press the button
.