7.3.6 Outside rim runout
Decreases the value
Increases the value
Confirms the default parameters
Goes back to the reserved setup screen
Return to main screen
Outside rimrunout: Enables/disables the outside rim runout measurement function
Inside first harmonic limit: Represents the threshold beyond which the first harmonic value read for
the rim inside is not considered acceptable.
Outside first harmonic limit: Represents the threshold beyond which the first harmonic value read for
the rim outside is not considered acceptable.
Inside peak/peak limit: Represents the threshold beyond which the peak/peak value read for the
rim inside is not considered acceptable.
Outside peak/peak limit: Represents the threshold beyond which the peak/peak value read for the
rim outside is not considered acceptable.
Default parameter setting: Resets the default machine settings.
Reserved Setup