Calibro a riposo
Piano flangia
0 Sonar
A
Use and maintenance manual Rev. 10-2011
ENGLISH
Th3. e number 69 ± 3° appears on the left display .
Turn the gauge downward positioning the gauge rod 4.
in contact with the spindle shell as shown in the
images.
The nu5.
mber 23 ± 3° should appear on the left
display. The calibration is already correct.
If not, press the
button holding the gauge: the
number 23 appears on the left display.
Return the gauge to rest position.
In the event of incorrect input in the diameter gauge calibration
function, press
to cancel it.
6.5.3 Width sonar (option)
Display the SETUP menu
P1. ress
/
to view the width sonar
CALIBRATION function.
Set with 2.
/
the distance in mm betwe
en the Sonar sensor (0 sonar) and the end of the
distance gauge (at rest).
A = Distance: Gauge at rest to
0 sonar
In the event of incorrect input in the width gauge calibration
function, press
to cancel it.