Owner's manual

CEMB SPA – Mandello del Lario
TECHNICAL CHARACTERISTICS
External connections : terminal board WEIDMULLER TOP 1,5 GS
Supply voltage : + 15 V / - 15 V
Max. current drawn : + 15 V = 120 A
- 15 V = 16 A:
of channels processed : 2
Unit of measurement of vibration : 0 to 100 µm, 0 to 300 µm
0 to 10 mm/sec 0 to 30 mm/sec
Output signals (terminals
OUT1 and OUT2) : 4 TO 20 mA proportional to the input vibration
Alarm contacts (terminals
ALARM 1 – ALARM 2) : 1 SPDT for each channel
Max. current, alarm contacts : 3A
Max. voltage, alarm contacts : 250 V
Alarm adjustment : 0 to 100% of the measurement range
Alarm delay time : from 0 to 20 seconds (approx.)
Alarm condition indicator : Red LED located close to the alarm level
setting potentiometer