Specifications
15
24
07
18
DPE *
DPE
Bits PE ...
(e.g. PE 95)
Bits PE ...
(e.g. PE 190)
7.2.2) Insert into the spindle shaft the DPE spacer required to activate the cooling device.
If necessary to use APE... adapter ( see pag.8) the bit must first be fitted in the
corresponding APE adapter and locked with the appropriate grub screw and then
the DPE spacer inserted.
Note: Adapters type APED… do not require use of DPE spacer.
7.2.3) Insert the bit-spacer unit in the spindle shaft so that the two engaging dogs on the
bit spigot line up with the grub screws. Press the bit-spacer unit home against
the inner seat of the spindle: this will enable the DPE spacer to open the
cooling circuit (see Fig. 10).
7.2.4) C
lamp the bit by fully tightening the two grub screws (18) using the 4 mm male
allen key.
FIG. 11 – MANUAL SPINDLE
ROTATION
FIG. 9 – ASSEMBLING THE SPIRAL BITS
FIG.10 – ASSEMBLING THE
BIT-SPACER UNIT
APE ...
²
* use only for APE..., not required for APED...
05
33
FIG. 20 – COOLANT OPERATION WITH BROACH CUTTER
Finish drilling
with removal of swarf and
switching off of
lubrocoolant
Approach
Start drilling
with discharge of
lubrocoolant
Drilling
FIG. 21 – COOLANT OPERATION WITH SPIRAL BIT
9.3) Drill fitted with special spiral bit
Follow the sequence described in § 9.1, taking care to position the drill on the rail by keeping
the spindle fully withdrawn. Bear in mind that the cooling circuit, instead of being
automatically opened and closed by the guide bit, is kept open at all times by the DPE spacer
fitted on the spigot of the spiral bit; it must therefore be activated, by opening the tap (02),
before starting to drill, then switched off after drilling by closing the tap.