Centennial CB12-105 Specifications

Specification
Cells Per Unit
Voltage Per Unit
Normal Operating Temperature Range
Capacity
Weight
Max. Discharge Current
Internal Resistance
Operating Temperature Range
6
12
o
100Ah@10hr-rate to 1.80V per cell @25 C
Approx. 30Kg/66.14 Lbs (Tolerance±2%)
1000A (5 sec)
Approx. 4.8 mΩ
Float charging Voltage
Recommended Maximum Charging
Current
Equalization and Cycle Service
Self Discharge
Terminal
Container Material
Terminal F12/F15
Dimensions
30 A
Unit: mm
o
Constant Current Discharge Characteristics: A (25 C)
o
Constant Power Discharge Characteristics: W(25 C)
F.V/Time
9.60V
10.0V
10.2V
10.5V
10.8V
11.1V
5MIN 10MIN 15MIN 30MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR1HR
F.V/Time
9.60V
10.0V
10.2V
10.5V
10.8V
11.1V
5MIN 10MIN 15MIN 30MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR1HR
Terminal F12
A.B.S. UL94-HB, UL94-V0 Optional.
320.7 226.9 181.4 112.7 65.00 38.89 26.88 22.03 18.03 12.42 10.50 5.78
311.4 215.8 177.7 110.8 64.70 38.60 26.78 21.93 17.93 12.32 10.40 5.67
302.2 208.2 174.9 109.8 64.10 38.31 26.57 21.83 17.82 12.22 10.30 5.57
271.3 192.1 166.5 107.1 63.50 38.02 26.47 21.62 17.61 12.12 10.20 5.46
244.9 175.2 153.5 102.4 62.00 37.33 25.75 21.11 17.29 11.92 10.10 5.36
209.1 156.6 137.7 95.91 58.90 35.68 24.62 20.09 16.55 11.41 9.80 5.04
3317 2416 1996 1284 751.1 458.4 319.9 262.6 215.1 148.3 125.5 69.26
3251 2342 1964 1269 749.3 456.0 320.0 262.3 214.6 147.6 124.7 68.06
3214 2280 1941 1260 743.5 453.3 318.6 261.7 213.9 146.6 123.6 66.80
2926 2123 1852 1230 736.8 450.0 317.4 259.3 211.3 145.4 122.4 65.54
2665 1957 1712 1179 723.2 444.2 308.7 253.4 207.5 143.0 121.2 64.28
2341 1770 1541 1108 692.3 427.7 295.4 241.1 198.6 136.9 117.6 60.50
All mentioned values are average values .( ±2%)Tolerance
Discharge: -20 C~60 C
o
o
Charge: 0 C~50 C
o o
Storage: -20 C~60 C
o o
o
o
25 C±5 C
o
13.6 to 13.8 VDC/unit Average at 25 C
o
14.6 to 14.8 VDC/unit Average at 25 C
RITAR Valve Regulated Lead Acid (VRLA) batteries can be stored
o
for more than 6 months at 25 C. Self-discharge ratio less than 3%
o
per month at 25 C. Please charge batteries before using.
o
105Ah@20hr-rate to 1.75V per cell @25 C
215
(12V105Ah)
CB12-105
Dimension: 306.5(L) ×168.5(W) ×210(H)×215(TH)/ 12.07(L) ×6.63(W) ×8.27(H)×8.46(TH) (inch)
Centennial AGM batteries are a perfect representation of stable quality and
high reliability batteries. Centennial's AGM sealed construction allows for
product with a low pressure venting system, makes it perfect in standby
applications. The ability to deliver high currents without significant drops in
voltage is what makes Centennial competitively exclusive in guaranteeing
customer satisfaction.
the battery to provide long life cycles. At the same time, being a maintenance-free

Summary of content (2 pages)