User guide

4
Reviewing the Heating Program
To review or edit the heating program use the PROGRAM or buttons to navigate
between the 4 individual programming periods.
Modifying the Heating Program
To change the heating program:
a.
Press either of the PROGRAM or buttons to
enter the programming mode. The time / temperature
settings for period
1
will be flashing as shown.
Theactiveperiodishighlightedbyaashingsquare
around the numbers at the bottom of the screen.
b. To adjust the period start time use the or buttons, the display will stop
flashing and the ‘OK?’ indicator will be displayed. Holding the button down will
changethetimequickly.Note: If you are pressing the
or buttons and the
display flashes the next period, it means the next period will be pushed forward.
c.Oncetherequiredtimeisreachedpressthe
button to confirm.
Note:Iftheoriginaltimesettingdidnotrequireadjustmentpressthe
button to
move to step ‘d’.
d. The temperature setting for period
1
will now be flashing. To adjust this press the
or buttons and confirm the setting again by pressing the button.
e. The next time and temperature period will now be active. Adjust this by repeating
steps b - d above until all 4 periods are set or press the AUTO button to run the
program as set, at any time.
Disabling / Enabling Time Periods
The thermostat has 4 periods that can be programmed, but you may not need all of
theseswitchpointsforyourheatingrequirements.Therefore,anyperiodfrom2to4
canberemovedfrom(orreturnedto)theheatingprogramprole.
4321
Programming the EHE0200153
Period 1 2 3 4
Time 6:30 8:00 18:00 22:30
Temperature 21°C 18°C 21°C 16°C
The Built-in Heating Program
The built-in heating program has 4 temperature level changes that can be set between
3.00am and 2.50am the following day - allowing you to maintain the evening
temperatureaftermidnight.Eachtemperaturelevelcanbesetbetween5°Cand35°C,
andadjustedin0.5°Cincrements.Thefactorydefaultprogramforheatingisasfollows.