user manual

SKU 92504 For technical questions, please call 1-800-444-3353. Page 12
To Turn Off The Air Compressor:
1. When finished using the Air Compressor, press down on its Power Switch (9) to
turn off the unit.
(See Figure E.)
2. Disconnect the Power Cord Plug (31) from its electrical outlet.
3. Turn on the pneumatic tools to expend all remaining compressed air from the Air
Compressor, air hoses, and pneumatic tools.
4. Turn the Pressure Adjustment Knob (6) counterclockwise all the way to its “OFF”
position. (See Figure E.)
5. Turn each Lever on the two Air Outlet Valves (4) backward to their closed position.
(See Figure E.)
6. Disconnect the air hoses from the Air Outlet Valves (4). (See Figure E.)
7. Disconnect the air hoses from the pneumatic tools. Then, keep the air hoses and
pneumatic tools in a clean, dry location out of reach of children.
INSPECTION, MAINTENANCE, AND CLEANING
1. WARNING! Always make sure the Power Switch (9) is in its “OFF” position,
the Air Compressor is disconnected from its electrical outlet, and all remaining
compressed air is expelled from the system before performing any inspection,
maintenance, or cleaning.
2. Before each use: Inspect the general condition of the Air Compressor. Check for
misalignment or binding of moving parts, cracked or broken parts, loose or damaged
connections, and any other condition that may affect its safe operation. If abnormal
noise or vibration occurs, have the problem corrected before further use. Do not
use damaged equipment.
3. Before each use: Make sure to fill the Air Compressor with a premium quality,
30 weight, non-detergent oil. Running the Air Compressor with no oil or low oil
will cause damage to the equipment and void its warranty. When filling the Air
Compressor with oil, make sure to unscrew (do not pull) the Oil Fill Cap (28) to
remove. Fill with oil until the level of the oil rises to the midway point in the Oil Level
Indicator (35). Then, screw the Oil Fill Cap back onto the Oil Fill Hole.
(See Figure F, next page.)