GUN ASSEMBLY
(6)
OLD FLUID CONTAINER
(4)
BRAKE BLEEDING HOSE
W/CONNECTOR
(5)
FIGURE C
9. Attach the Brake Bleeding Hose w/Connector (5) to the Bleeder Screw on the
vehicle wheel. Then, connect the air compressor’s air hose to the Handle of the
Gun Assembly (6). (See Figure D.)
10. Turn on the air compressor, and set its regulator at 90 to 120 PSI.
Do not exceed 120 PSI. (See Figure A.)
11. Squeeze the Lever of the Gun Assembly (6) to create a vacuum in its Old Fluid
Container (4). (See Figure D.)
AIR HOSE
(NOT INCLUDED)
BRAKE BLEEDING HOSE W/CONNECTOR (5)
GUN ASSEMBLY (6)
BLEEDER SCREW
VEHICLE WHEEL
OLD FLUID CONTAINER (4)
FIGURE D