User's Manual

© 2015 CentraLite. All rights reserved.
Data Sheet: 3-Series Smart Garage System (3220) Page 4 of 5
Online Resources
To access a digital version of this document, please
visit www.CentraLite.com.
Standard WarrantySupport
Contact Sales
CentraLite offers a standard 12-month limited
warranty on the 3-Series Smart Garage System.
CentraLite offers both Tier-1 and Tier-2 support
structures to meet the needs of different customers.
For those customers that provide existing, in-house
support for systems, CentraLite can serve as Tier-
2 support specialists. For CentraLite retail-branded
products, CentraLite provides direct Tier-1 support
for all products.
For more information about sales or distribution,
please contact:
Sean Bryant, VP Sales & Marketing
877-466-5483
seanbryant@centralite.com
CentraLite Systems, Inc.
1000 Cody Road
Mobile, AL 36695
www.centralite.com
Compatibility
The 3-Series Smart Garage System features out-of-the-box compatibility with any ZigBee HA 1.2-certied hub,
controller, bridge, or platform.
Technical Specications
Electrical
Controller Power: 120 VAC, 60Hz
Sensor Power: 1x CR-2450 Battery
Environmental
Operating Temperature: 0° to 40°C
Shipping / Storage
Temperature: -20° to 50°C
Humidity Range: 0 to 90% R.H.
(non-condensing)
Approvals:
Wireless RF
Protocol: ZigBee HA 1.2
TX Strength: +20 dBm
RF Channels: 16
Range: 50+ ft.
Troubleshooting
Step 1: Check Power Status of Smart Garage
Controller.
Ensure that the Smart Garage Controller’s LED status
ring is lit and green. If not, ensure that power is
getting to the receptacle. (Note: if the garage door
motor is powered by the same receptacle as the
Smart Garage Controller, ensure that the garage door
motor is functioning correctly on its own.)
Step 2: Reset and Rejoin Garage Controller
Remove the device from your hub or ZigBee
controller and then open the hub for joining. Then,
using an extension pole or ladder, depress the Smart
Controller’s multi-button (center of the LED ring) for
15 seconds and the Garage Controller will reset and
attempt to rejoin the ZigBee Network.