Installation manual
Figure 10 Determining Wall Bracket Position for Perpendicular Wall Mount
PERPENDICULAR WALL MOUNT
FOR INSTALLATIONS WHERE
O
THE GATE OPENS 90 OR LESS
FOR INSTALLATIONS WHERE THE
O
GATE OPENS MORE THAN 90
Page 19
o
110
o
120
o
100
o
90
o
80
o
70
o
60
Gate opening angle
o
0
b
#
A
B
C D
Gate Opening
Angle (Degrees)
170 to 350 (210)
230 to 370 (270)
290 to 400 (330)
340 to 410 (380)
50 to 220 (140)
50 to 220 (180)
50 to 140 (80)
50 to 140 (80)
(700) (480)
(500)
(500)
(700)
(610)
90
100
110
120
Hinge Centre to
Gate Bracket
Drive Arm
Length
Gate Centre to
Bracket Centre
Hinge Centre to
Mounting Face
60
70
80
140 to 180 (140)
180 to 220 (180)
180 to 260 (180)
50 to 220 (180)
50 to 220 (180)
50 to 220 (140)
(700)
(700)
(700)
(700) (420)
(350)
(300)
(250)
100
272,2
1
10
© Centurion Systems (Pty) Ltd.
GATE LEAF IN CLOSED POSITION
b
C
#
A
B
D
#
50mm
W
all Mount
Bracket
C
GATE LEAF IN CLOSED POSITION
b
#
A
o
90
D
#
50mm
W
all Mount
Bracket
BE SURE TO USE A ‘SHORT’
CONNECTING ARM FOR THIS
INSTALLATION TYPE.
Ensure that the gate does not exceed the relevant specifications on page9.
Recommended values are shown in bold type.
All dimensions shown are indicated in millimetres.
All recommended values will result in gates with similar opening times.
#The minimum value will ensure a clearance of 30mm if the gate is 50mm thick