Installation manual

23. If no additional Features are required, then exit programming mode by removing the SET link. Store
the link by pushing it over ONE of the two pins.
(See Set-up Troubleshooting Guide step 23)
24. Open and close the gate a few times to check operation.
(See Set-up Troubleshooting Guide step 24)
Setting Additional Features (Optional)
The default factory settings on the CP75 Controller have been selected to suit most applications. In many
cases there would be no need to change the default settings. A list of features can be found on page 47,
with a detailed description of each feature on page 32.
Determine What Features are Required
25. Determine from Table 2 on Page 47 what Features are required together with the STATUS or COUNT
value.
Example: “To turn the AUTO-CLOSE Feature ON”: According to Table 2 the auto-close feature is
Feature number 2, and to turn it ON is a status of 1.
Get Into Programming Mode (Exactly the same as for limits setup)
26. Remove ALL power from the controller, i.e. charger plug and battery.
27. Fit the SET link to the SET pins as shown in figure 28.
28. Reapply power by reconnecting the charger plug, and then the battery to the controller.
29. Immediately after reconnecting the power, the STATUS light must flash 5 times, and then SET and L2
will come on. You are now in programming mode.
Page 30
by pressing, holding and releasing the test button, as in step 19 and 20.
21. Then press and release the TEST button once more to confirm the OPEN limit.
When setting Master motor limits:
22. The gate will close completely, pause and
then open to the minimum pedestrian
position.
If a larger pedestrian opening is required,
momentarily short the PED input to COM to
jog the master leaf further open.
At the required position, press and
release the TEST button.
The MASTER gate will open fully, then the
SLAVE gate (where fitted) will close
slightly. The STATUS light will flash 5 times,
and L2 will come on, to indicate that the
limits were set.
The control card has now returned to the
initial programming mode.
When setting Slave motor limits:
The gate will close slightly. The STATUS light will flash
5 times, and L2 will come on, to indicate that the limits
were set.
The control card has now returned to the initial
programming mode.