Installation manual
SPECIFICATION R3 R5
Input Voltage* 220V AC ±10% 50Hz 220V AC ±10% 50Hz
AC Current draw (with C84E Battery Charger) 120mA 120mA
DC Motor Voltage 12V 12V
DC Current draw (Max) 30A 35A
Maximum solenoid lock current draw 2A 2A
Output shaft rotational speed 3.5 rpm 2.6 rpm
Maximum output torque 95Nm 250Nm
Mass of master motor kit (excluding pedestal or wall bracket) 14.4kg 15,5kg
Mass of slave motor kit (excluding pedestal or wall bracket) 12.9kg 14,0kg
Maximum number of operations per day (Average):
Light industrial, with 10A power pack (PSU) 100 250
Domestic, with 1A Battery Charger (CP84E) 20 20
Maximum number of continuous operations 20 100
Typical time to open/close a gate 10 seconds 13 seconds
(For standard pedestal in recommended position)
No. of operations on a 7A/H battery (should the mains power fail) ±20 ±20
Limit switches Sealed optical counter Sealed optical counter
with origin switch with origin switch
Collision sensitivity Electronic adjustable Electronic adjustable
Temperature range -20º to +50ºC -20º to +50ºC
Housing protection IP55 IP55
Control card (single or double motor) CP75 CP75
Corrosion protection (baseplate and arms) Zinc passivation with Zinc passivation with
lacquer impregnation lacquer impregnation
Page 9
*Other voltages are available