Installation manual
01
0
97
81
5
011
Figure 7 Pedestal Positioning for Standard Installations
o
110
o
120
o
100
o
90
o
80
o
70
o
60
Gate opening angle
o
0
β
#
A B
C E
Gate Opening
Angle (Degrees)
60 224350 to 610 (370)
320 to 600 (340)
240 to 530 (260)
200 to 450 (220)
210 to 400 (230)
250 to 440 (330)
280 to 440 (300)
550 to 790 (750)
550 to 790 (750)
550 to 790 (750)
550 to 740 (700)
500 to 740 (700)
450 to 640 (600)
300 to 490 (450)
650 to 700 (700)
650 to 700 (700)
650 to 700 (700)
650 to 700 (700)
600 to 650 (650)
500 to 610 (610)
500 to 570 (570)
70 191
80 153
90 110
100 122
110
120
130
130
Gate Centre to
Pedestal Centre
Hinge Centre to
Pedestal Centre
Hinge Centre to
Gate Bracket
Pedestal to
edge of motor
!
Ensure that the gate does not exceed the relevant specifications on page 9.
!
Recommended values are shown in bold type.
!
All dimensions shown are indicated in millimetres.
!
All recommended values will result in gates with similar opening times.
#The minimum value will ensure a clearance of 30mm if the gate is 50mm thick
Where to Position the OperatorWhere to Position the Operator
PEDESTAL POSITIONING FOR
STANDARD INSTALLATION
(SMOOTHEST MOVEMENT, BEST LOCKING)
© Centurion Systems (Pty) Ltd.
BE SURE TO USE A ‘LONG’ CONNECTING ARM
FOR THIS INSTALLATION TYPE.
Page 16
C
GATE LEAF IN CLOSED POSITION
β
B
158
E
d
st
P
ee
l
a
#
m5
m0
#
A
A
L
N
O
G
T
O
P
I
N
E
A
F
I
N
S
I
OE
P
E
T
PEDESTAL POSITIONING FOR
INSTALLATIONS WITH LIMITED SPACE
β
#
A B
C D E F
Gate Opening
Angle (Degrees)
170 to 360 (170)
210 to 400 (210)
250 to 440 (250)
280 to 420 (280)
700 to 840 (800)
550 to 840 (800)
450 to 640 (600)
350 to 540 (500)
550 to 610 (610) 500 (464) 122 332
500 to 590 (590) 500 (487) 130 380
500 to 570 (570) 500 (496) 130 410
90
100
110
120
Hinge Centre to
Gate Bracket
Drive Arm
Length
Edge of Motor to
Pedestal Centre
Gate Centre
to Wall
Hinge Centre to
Pedestal Centre
60
70
80
190 to 390 (190)
190 to 380 (190)
180 to 370 (180)
800 to 890 (850)
750 to 890 (850)
750 to 840 (800)
800 (800) 475 (419) 224 414
700 to 750 (750) 500 (444) 191 381
650 to 700 (700) 500 (461) 153 333
600 to 650 (650) 500 (459) 110 280
Figure 8 Pedestal Positioning for Installations with Limited Space
1
00
79
8
5
1
01
1
o
110
o
120
o
100
o
90
o
80
o
70
o
60
Gate opening angle
o
0
© Centurion Systems (Pty) Ltd.
Gate Centre to
Pedestal Centre
GATE LEAF IN CLOSED POSITION
GA E F
N PO I
NTE L A N
O
PE SI
TI O
β
B
E
D
#
A
C
#
50 m
m
F
i
n m
td
s l
Pe
ea
BE SURE TO USE A ‘LONG’ CONNECTING
ARM FOR THIS INSTALLATION TYPE.
Page 17
!
Ensure that the gate does not exceed the relevant specifications on page 9.
!
Recommended values are shown in bold type.
!
All dimensions shown are indicated in millimetres.
!
All recommended values will result in gates with similar opening times.
#The minimum value will ensure a clearance of 30mm if the gate is 50mm thick