Installation manual

PEDESTAL POSITIONING FOR OUTWARD OPENING GATES
β
#
A B
C
Gate Opening
Angle (Degrees)
100 to 400 (120)
100 to 400 (120)
100 to 380 (120)
100 to 260 (120)
520 to 640 (580)
440 to 660 (580)
360 to 620 (400)
340 to 580 (480)
550 to 600 (600)
550 to 600 (600)
550 to 650 (650)
90
100
110
120
Hinge Centre to
Gate Bracket
Gate Edge or
Hinge Point to
Shaft Centre
Hinge Centre to
Shaft Centre
60
70
80
240 to 530 (250)
150 to 440 (160)
100 to 400 (120)
600 to 660 (640)
580 to 640 (620)
560 to 660 (580)
500 (500)
500(500)
500 to 550 (550)
550 to 600 (600)
o
110
o
120
o
100
o
90
o
80
o
70
o
60
Gate opening angle
o
0
Figure 9 Pedestal Positioning for Outward Opening Gates
001
79
5
81
10
1
It is recommended to fit end stops in
the open position of the gate to
reduce gate movement when open.
© Centurion Systems (Pty) Ltd.
B
#
A
A N ON
GAT L F N O IT
E E PE POS I
I
β
C
GATE LEAF IN CLOSED POSITION
SE
N
D TOP
#
5m
0
m
tds
lPe
ea
BE SURE TO USE A ‘LONG’ CONNECTING ARM
FOR THIS INSTALLATION TYPE.
Page 18
!
Ensure that the gate does not exceed the relevant specifications on page 9.
!
Recommended values are shown in bold type.
!
All dimensions shown are indicated in millimetres.
!
All recommended values will result in gates with similar opening times.
#The minimum value will ensure a clearance of 30mm if the gate is 50mm thick
Figure 10 Determining Wall Bracket Position for Perpendicular Wall Mount
PERPENDICULAR WALL MOUNT
FOR INSTALLATIONS WHERE
O
THE GATE OPENS 90 OR LESS
FOR INSTALLATIONS WHERE THE
O
GATE OPENS MORE THAN 90
Page 19
o
110
o
120
o
100
o
90
o
80
o
70
o
60
Gate opening angle
o
0
β
#
A B
C D
Gate Opening
Angle (Degrees)
170 to 350 (210)
230 to 370 (270)
290 to 400 (330)
340 to 410 (380)
50 to 220 (140)
50 to 220 (180)
50 to 140 (80)
50 to 140 (80)
(700) (480)
(500)
(500)
(700)
(610)
90
100
110
120
Hinge Centre to
Gate Bracket
Drive Arm
Length
Gate Centre to
Bracket Centre
Hinge Centre to
Mounting Face
60
70
80
140 to 180 (140)
180 to 220 (180)
180 to 260 (180)
50 to 220 (180)
50 to 220 (180)
50 to 220 (140)
(700)
(700)
(700)
(700) (420)
(350)
(300)
(250)
0
1
0
7
2,
2
2
1
1
0
© Centurion Systems (Pty) Ltd.
GATE LEAF IN CLOSED POSITION
β
C
#
A
BB
D
#
0m
m
5
a u
ll
M
t
W
o
n
aB
rke
ct
BB
C
GATE LEAF IN CLOSED POSITION
β
#
A
o
90
D
#
0
m
m
5
#
0
m
m
5
a M
u t
W
ll
o
n
a
e
B
rckt
BE SURE TO USE A ‘SHORT’
CONNECTING ARM FOR THIS
INSTALLATION TYPE.
!
Ensure that the gate does not exceed the relevant specifications on page9.
!
Recommended values are shown in bold type.
!
All dimensions shown are indicated in millimetres.
!
All recommended values will result in gates with similar opening times.
#The minimum value will ensure a clearance of 30mm if the gate is
50mm thick