User guide

Introduction
The R3 and R5 Rotary arm operators are fitted with the CP75 controller. The controller synchronizes the
functions of the gate operator.
Modes of Operation
There are four different modes of operation that can be selected. Only one mode can be selected at any
one time.
STANDARD (with selectable auto close* feature)
REVERSING (with selectable auto close* feature)
CONDOMINIUM (compulsory auto close*)
PIRAC (compulsory auto close*)
STANDARD MODE is the most common. The other modes are usually used for specialist applications.
*The auto-close feature is described under the section “Automatic Closing”
STANDARD MODE OF OPERATION
The gates are opened in the following way:
Radio Transmitter
A hand held radio transmitter, carried in the motor vehicle, sends a coded signal to the receiver mounted
in the control enclosure to open or close the gate.
If the automatic closing facility has been selected, and the gate is closing automatically, then the gate will
stop and stay in that position if the transmitter is pressed. Pressing the button again will cause the gate to
reopen.
Features & Functions
Radio Receiver
Page 6
Hand held transmitter sends coded signal Receiver uses signal to open or close the gate
!
Press once for approximately 1 second to get the gate into motion.
!
If the transmitter is pressed while the gate is either opening or closing the gate will immediately stop.
Pressing the button again will cause the gate to reverse.