Instructions / Assembly

506842-01Page 34 of 42 Issue 1132
Blower Data GUH80C
GUH80C090C5M PERFORMANCE (Less Filter)
External
Static
Pressure
in. w.c.
Air Volume / Watts at Different Blower Speeds
Bottom Return Air, Side Return Air with Optional Return
Air Base, Return Air from Both Sides or Return Air from
Bottom and One Side.
Single Side Return Air í Air volumes in bold require field
in order to maintain proper air velocity.
High Medium-High Medium-Low Low High Medium-High
Medium-Low Low
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
cfm Watts cfm Watts
0.00 2255 640 1940 420
1750
310 1485 185 2290 655 1980 425
1605 235 1495 195
0.10 2200 655 1910 440
1705
315
1385 190 2250
675
1945 445
1555 245 1400 190
0.20 2150 675 1865 450
1655
340
1340 205 2210 695 1885 465
1510 265 1350 205
0.30 2125 695 1835 475
1635
355
1285 215 2165
715
1850 475
1470 275 1285 215
0.40 2090 715 1800 495
1585
370
1235 230 2135 720 1810
490
1410 290 1225 230
0.50 2060 735 1760 510
1545
385
1200 245 2070 735 1765 515
1370 305 1180 245
0.60 2020 750 1725 525
1515
405
1145 255 2030
760
1715 530
1325 320 1140 255
0.70 1980 765 1680 540
1465 420
1105 270 1990 775 1685 540
1265 330 1095 270
0.80 1935 785 1635 560
1420
435
1055 285 1950 795 1645 560
1225 345 1040 285
cfm
Medium
Watts
Medium
cfm Watts
fabricated transition to accommondate 20 x 25 x 1 in. air filter
1580
1535
1490
1450
1405
1370
1320
1265
1225
230
240
260
275
285
305
320
330
350
1775
1730
1680
1645
1595
1545
1495
1450
1415
310
320
340
355
370
390
405
425
435
GUH80C110C5M PERFORMANCE (Less Filter)
External
Static
Pressure
in. w.c.
Air Volume / Watts at Different Blower Speeds
Bottom Return Air, Side Return Air with Optional Return
Air Base, Return Air from Both Sides or Return Air from
Bottom and One Side.
Single Side Return Air í Air volumes in bold require field
in order to maintain proper air velocity.
High Medium-High Medium-Low Low High Medium-High
Medium-Low Low
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
cfm Watts cfm Watts
0.00 2230 635 1945 430
1715
295 1470 185 2315 645 1990 415
1610 230 1510 200
0.10 2180
655
1905 445
1690
305
1340 175 2260
655
1945 425
1550 240 1400 185
0.20 2135
680
1865 465
1630
330
1280 190 2210 680 1895 450
1510 255 1350 200
0.30 2090 695 1830 480
1595
345
1235 200 2165
700
1850 465
1455 275 1285 210
0.40 2050
715
1785 495
1550
360
1175 210 2135
715
1830
485
1395 285 1230 225
0.50 2025
730
1740 520
1500
375
1130 225 2095 730 1770 500
1365 300 1175 235
0.60 2010 750 1710 535
1470
390
1080 240 2055
755
1725 515
1305 315 1135 250
0.70 1965
755
1670 555
1420 410
1015 255 1675 535
1255 325 1080 265
0.80 1905
785
1635 560
1380
425
975
270 1640 555
1210 345 1025 275
cfm
Medium
Watts
Medium
cfm Watts
fabricated transition to accommondate 20 x 25 x 1 in. air filter
1555
1510
1470
1440
1385
1340
1305
1255
1215
230
240
260
275
285
300
320
330
350
1780
1740
1680
1650
1585
1535
1495
1465
1400
300
315
335
355
365
385
400
410
425
1965
2000
785
765
GUH80C135D5M PERFORMANCE (Less Filter)
External
Static
Pressure
in. w.c.
Air Volume / Watts at Different Blower Speeds
Bottom Return Air, Side Return Air with Optional Return
Air Base, Return Air from Both Sides or Return Air from
Bottom and One Side.
Single Side Return Air í Air volumes in bold require field
in order to maintain proper air velocity.
High Medium-High Medium-Low Low High Medium-High
Medium-Low Low
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
cfm Watts cfm Watts
0.00 2495 755 2295 590
2045
435 1650 230 2365 725 2295 575
1820 300 1635 235
0.10 2440
780
2220 620
2015
445
1615 245 2350
745
2210 595
1745 320 1530 230
0.20 2390
790
2175 640
1935
470
1550 255 2330 775 2175 625
1730 330 1490 250
0.30 2360 805 2140 655
1895
490
1485 275 2245
785
2135 645
1655 355 1425 265
0.40 2285
835
2125 675
1850
510
1455 290 2215
810
2085
660
1600 375 1385 285
0.50 2240 860 2060 690
1815
535
1415 310 2175
825
2045 680
1590 390 1340 290
0.60 2225 865 2015 715
1785
550
1330 320 2125
845
1995 700
1525 405 1300 310
0.70 2160
895
1955 735
1755 570
1265 340 1950 710
1485 420 1260 325
0.80 2105 905 1925 750
1715
580
1215 345 1890 725
1415 445 1205 345
cfm
Medium
Watts
Medium
cfm Watts
fabricated transition to accommondate 20 x 25 x 1 in. air filter
1845
1820
1735
1720
1660
1610
1535
1500
1435
315
330
350
370
380
400
420
440
450
2005
2000
1945
1895
1840
1815
1765
1700
1680
410
435
455
475
495
505
530
545
656
2065
2095
880
865