Specification

3
GUH95T Models -060B4 -080C5 -100C5 -120D5
Input-BTUH—High Fire
1
60,000 80,000 100,000 120,000
Input-BTUH—Low Fire 39,000 52,000 65,000 78,000
Heating Cap. BTUH—High Fire 57,000 76,000 95,000 114,000
Heating Cap. BTUH—Low Fire 37,050 49,400 61,750 74,100
AFUE 95.1% 95.1 95.1 95.1
Blower D x W 11 x 8 11 x 10 11 x 10 11 x 10
Motor HP - Type 1/2 - BLDC 3/4 - BLDC 3/4 - BLDC 1.0 - BLDC
Motor FLA 6.2 8.7 8.7 11.7
Rated Ext. SP in W.C. 0.5 0.5 0.5 0.5
Temp. Rise Range
o
F 30 - 60 35 - 65 35 - 65 40-70
Power Supply 115-1-60 115-1-60 115-1-60 115-1-60
Shipping Weight (lbs/kg) 125/56.7 135/61.2 145/65.8 160/72.6
Specications
T=Two Stage/
Variable
Speed ECM
UH=Upow/
Horizontal
Gas
Furnace
AFUE
95%
Heating Input
BTUH
060=60,000
120=120,000
Cabinet
Width
B=17
1
/2"
C=21"
D=24
1
/2"
Max. CFM Cooling*
4=1600 CFM
5=2000 CFM
*Airow @ 0.5 ESP
or 400 CFM/ton
X=Low Nox Series/
Revision
G UH 95 T 060 B 4 X E
Model Nomenclature
* Factory setting
Gas connection for all models is 1/2" N.P.T.
1
Ratings to 2,000 ft. Over 2,000 ft, reduce 4% for each 1,000 ft. above sea level.
95% Two Stage Accessories
PART NO. DESCRIPTION
904952 2" Concentric vent kit
904953 3" Concentric vent kit
904617 2" Side wall vent kit
904347 3" Side wall vent kit
PART NO. DESCRIPTION
905028 U.S. LP conversion kit (0 - 10,000 ft.)
905029 Canada LP conversion kit (0 - 4500 ft.)
541036 Side return filter kit
902377 Neutralizer kit
Category IV Venting System: Units may be vertically or horizontally vented
using either a one-pipe or two-pipe system, allowing maximum flexibility in installation.