Specification

7
Features and Benefits
Quiet Operation—Blower compartment has sealed door
and insulation to lock in heat and sound; sealed vestibule reduces
burner and inducer sound levels; plus two stage inducer and
ECM blower motor make this one of the quietest furnaces on the
market
Extraordinary Efciency—Two heat exchangers
deliver 95%+ of the heated air to the home, while the two stage
inducer optimizes first stage efficiency; the ECM blower motor
gives up to 1 SEER point gain in cooling efficiency
ECM Blower Motor—Runs at a variety of speeds to match
the load demand, for efficiency and quiet operation. Constant
air flow through a wide variety of ductwork conditions reduces
temperature stratification while improving indoor air quality
Hot Surface Igniter—Silicon nitride type igniter is
automatic, eliminating the need for a standing pilot light
Designed for Long Life—Primary heat exchanger
is made of heavy gauge aluminized steel and secondary heat
exchanger is made of stainless steel; cabinet is steel with
corosion resistant finish
Thermostat—Can be used with either a single or two-stage
thermostat; two stage is recommended for optimal efficiency (not
included with furnace)
Save space as well as energy!
At just 34 ½” high, our two stage furnace is a real space miser. While it’s
great for new construction, this energy efficient series is also ideal for
replacements because it can fit in the space of virtually any older furnace.
Its light weight and small dimensions make even bigger capacity models
easy to unload and move up or down stairs and through doorways during
installation. And the low profile design leaves plenty of room for add-ons,
including the new higher SEER coils with taller cabinets.
Easily converted to L.P. (propane)
Kits are available to allow a trained installer to convert the furnace to L.P.
gas source quickly and easily in the field. All that’s needed is a simple
burner orifice and regular spring change.
34
1
/2
Features and Benets
On-Board Diagnostics—Unlike
some units that require counting flashes to
determine the problem, the GUH95T has a
dedicated light for flame signal strength, and
two lights that illuminate in combination for
easily recognized fault codes