10
e Control lamp illuminates if the device is switched on
f Control lamp, batteries
green illuminates constant UB > 3,6V
green flashes 3,4V < UB 3,6V
red flashes UB 3,4V, approx. 30 minutes operating time
LED OFF UB 2,7V, no function
g Red push button OFF to switch off the device
h Cap for the 9-pin plug (item »h«)
I External push button for subscription of max. four CT-DECT Multi (Man-Pac) to the CT-DECT Case
(8). These four CT-DECT Multi (Man-Pac) can be subscribed by the external push button to the
CT-DECT Case (8) without opening the case.
The push button has equal functional rights as the internal button »1/extern« (item »b«) in the case
j 9-pole plug for connection the CT-DECT Case (8) to a aircraft interface via an aircraft specific
adapter cable
Î PLEASE NOTE:
When using the CT-DECT Case (8) via the aircraft-specific CT adapter cable, without connection
to the aircraft’s intercom system, the sealing cap should always be plugged onto the unused 9-