CT-DECT Multi M7 Configuration 2400105 Operating manual English – USA dok1702-us-07-0221
Contents 1 2 General Operating- and Safety Instructions .................................................................................... 2 Purpose .......................................................................................................................................... 7 2.1 Profiles..................................................................................................................................... 7 3 Technical description ...............................................
⚫ Let devices that are designed for outdoor use during use outdoors always closed (e.g. CT-DECT Case) and close unused ports with appropriate cover – if available. ⚫ Do not store CeoTronics products in the open air or in damp ambient conditions. At all times keep them clean, dry and at normal air humidity. CeoTronics pro- ducts must not be stored in areas with a temperature of over +80° C (+176° F), e.g. in the summertime on the parcel shelf of a car.
It is important that you strictly observe the guidelines, arrangements and regulations applicable to your area of activity! Risk of electric shock! ⚫ Before opening line voltage operated products (e.g. for service purposes), always disconnect first the mains plug from the mains socket! ⚫ Use CeoTronics products only in undamaged condition. In case of any kind of damage, refrain from further using the CeoTronics product and have it repaired.
Important safety information concerning the use of CT-DECT digital radio systems! ⚫ Legal note for operation in the European Union The transmitter of the CT-DECT device should be used in the European Union only when it is marked as following: ⚫ Legal note for operation in the USA The transmitter of the CT-DECT device should be used in the USA only when it is marked as following: Improper use! The use of CeoTronics products for special applications, such as explosive and hazardous areas, aviation, bomb dis
Important Notes for operation of the CT-DECT System in the USA Please note that any changes or modifications not expressly approved by the party responsible for compliance will void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Definition FP = Fixed Part (Base / Basis) – e.g. CT-DECT Case PP = Portable Part (Standard / Mobilteil) DNR = Digital Noise Reduction (Digitale Unterdrückung störender Geräusche) Sidetone = S/T audible feedback of your voice GC Multi = Profile for GateCom Multi (aircraft ground handling) 2 Purpose The CT-DECT Multi M7 is a mobile communication device based on DECT radio technology. It enables the user to connect wirelessly to a CT-DECT network and thus use a voice communication (full duplex).
1 Standard Standard Standard Base All users can communicate with each other in full duplex.
2 GC Multi GC Multi GC Multi GC Multi Intercom Base All users with profil „GC Multi“ and the Intercom can communicate in full duplex. Suitable adapter cables are available for various intercom systems. Please contact us to select the appropriate adapter cable for your application.
3 Technical description 3 - Operating elements Microphone On/Off Accessory connector (for connection of headset) CT-ComLink® SF Battery status LED Catch-cord fastener Battery compartment Display Volume + PTT Volume - Softkey 1 On-/Off button Softkey 2 dok1702-us-07-0221 Fixing clamp 10 / 20
3.1 Plug connections 4 - Connect and disconnect the plug connection Place the plug on the socket. Make sure that the red dot on the plug and socket match. Turn the plug carefully on the socket until it something slides into the socket. Press the plug into the socket until you feel it lock into place. To disconnect the plug, grasp only the front part of the plug and carefully pull the plug out of the socket. CAUTION The locked connector must neither be twisted (Figure 5) nor kinked (Figure 6).
7 NO 4 Switch-on Press on/off button until display starts. The display first shows the current profile 5 Switch-off Keep the On/Off button pressed until “Shutdown” appears on the display – press the button again to confirm. 6 Display 8 DECT display – signal strength Speaker volume / On/Off Battery status Microphone On/Off Profile Name Status line STANDARD 7 Menu 7.
7.2 Menu structure 7.2.
7.2.
8 Setting the profile You can change the profile as follows: Switch the device off - Keep the On/Off button pressed until “Shutdown” appears on the display – press the button again to confirm. Switch-on - Press on/off button and Softkey 2 until display starts.
10 Pairing – Bluetooth (only in profile „Expert“) In the "Expert" profile, a Bluetooth device can also be additionally paired with the CT-DECT Multi M7. Step 1 – Switch On the Bluetooth function in CT-DECT Multi M7 Press up to Press up to EXPERT X MENU Press BLUETOOTH DECT --) X MENU Press --) X MENU --) Press ON OFF ON X OFF --) EDIT Press ON X OFF OK ON --) X OFF OK --) Step 2 Set the desired Bluetooth device to pairing mode.
13 Power supply – Battery change Power is supplied by a Li-Po battery pack or by 3 AAA cells, which are inserted into the device in a special adapter. Alkaline or NiMH batteries can be used in the adapter. Batteries and accumulators must not be mixed in the adapter. A runtime display is only possible when using the Li-Po battery pack. Depending on the ambient temperature, the headset is used and the intensity of use (transmission / reception / standby), operating times of up to approx.
13.1 Display remaining capacity Press up to Press up to DECT DECT STANDARD X MENU --) Press X MENU Press for select INFO --) X OK 31% --) X ZUSTAND --) The remaining capacity can be requery via the menu (see diagram).
The following charger is available for charging the Li-Po battery packs: Article Number 4-Slot battery charger 4024003 14 Servicing and maintenance 14.1 Condition check Regularly inspect the system – and especially cables and connectors – for signs of breakage, cracking, and wear. 14.2 Cleaning Remove any loose dust with a soft brush. Clean the outside with a suitable clean cloth that has been slightly moistened with clear water, and rub the parts dry afterwards.
Certificate No.: 01100004023 (ISO9001) Certificate No.: 01220004023 (ATEX, Directive 2014/34/EU) Certificate No.: 461801 (PPE, Regulation (EU) 2016/425) Deutschland und Internationaler Vertrieb CeoTronics AG Adam-Opel-Str. 6 63322 Rödermark Tel. +49 6074 8751-0 Fax +49 6074 8751-676 E-Mail verkauf@ceotronics.com USA/Kanada/Mexico CeoTronics, Inc. 2133 Upton Drive, Suite 126, PMB 513 Virginia Beach, VA 23452 Tel. +1 757 549-6220 Fax +1 757 549-6240 E-Mail sales@ceotronicsusa.com Spanien CeoTronics S.L.