User's Manual Part 9

Notice
The installation, maintenance, or removal of antenna sys-
tems requires qualified, experienced personnel. This
installation instructions have been written for such person-
nel. Antenna systems should be inspected once a year by
qualified personnel to verify proper installation, mainte-
nance, and condition of equipment.
results of improper or unsafe installation practices.
1
Tightly attach the
crossbars to the channel
for the desired offset of
the center of the antenna
16
16
17
17
13
28
Antenna center
offset left
(rear view)
Antenna center
offset right
(rear view)
19
19
13
Description
This mount is designed to be attached to an
antenna reflector and to provide for mounting the
antenna on a 4-1/2" (114 mm) diameter vertical tower
pipe. A strut is used to connect the bottom of the mount
to a tower member for extra stability.
The antenna center can be located 10.4" (264 mm) from
either side of the vertical tower pipe center, depending
on how the mount is assembled. This provides the
clearance necessary for the antenna feed components
and connections.
The mount includes separate turnbuckles for plus or
minus 15° azimuth adjustment and plus or minus 20°
elevation adjustment.
1
2
VP antenna
1
23
VHP antenna
Antenna Assembly Sequence
Ceragon disclaims any liability or responsibility for the