Installation Instructions Chapter 4

FibeAir 1500 Installation & Operation Manual Chapter 4. System Setup
4-26 External Alarms Setup Revision 2.0
4.8. External Alarms Setup
The procedure detailed in this section is required only if external equipment
alarms are connected to the IDU or if the IDU alarm outputs are connected
to other equipment (using the alarms I/O connector).
1. To define IDU Configuration select Configuration ½ IDU.
The IDU Configuration window is displayed.
Figure 4-18 IDU Configuration Window
Follow the steps below for both the Local and Remote sides:
4.8.1. Setting External Alarm Inputs
The microcontroller in the IDU reads the alarm inputs (dry contact) and
transmits them over the management channel to the GiganetView
management system. This allows the FibeAir 1500 system to report external
alarms not related to itself. For each alarm:
1. Click on the box next to the alarm number to enable/disable. Alarms that
are enabled are indicated by a filled box (n); disabled alarms are
indicated by (o).
2. Enter a description of the alarm.
3. Select the alarms severity (Major, Minor, Warning or Event).