Installation & Operation Manual Chapter 2

FibeAir 1500 Installation & Operation Manual Chapter 2. Theory of Operation
Revision 2.0 System Specifications 2-9
2.4.6. Network Management, Diagnostics, Status and Alarms
Type SNMP, in compliance with RFC 1213, RFC 1595 (Sonet MIB)
Local or Remote
NMS Station
GiganetView
TM
with advanced GUI for Windows 95/98/NT
TM
or UNIX
TM
,
integrated with HP OpenView
TM
NMS Interface Ethernet bridge 10Base-T, RS-232 (PPP, SLIP)
Local Configuration
and Monitoring
Standard ASCII terminal, serial RS-232
Cascaded Topology Internal IP routing allows cascaded link topology
TMN Giganet NMS functions are in accordance with ITU-T recommendations for TMN.
Interconnection to TMN is available via Q3 interface upon specific requirement
External Alarms 8 Inputs, TTL-level or contact closure to ground, 5 Outputs, Form C contacts,
software configurable
RSL Indication Accurate power reading (dBm) available at IDU, ODU and NMS
Performance
Monitoring
Integral with an on board memory per ITU-TG.826
2.4.7. Environmental
Operating Temperature
(Guaranteed Performance)
ODU: -35oC to 55oC
IDU: -5oC to 45oC
Relative Humidity ODU: up to 100% (all weather operation)
IDU: up to 95% (non-condensing)
Altitude Up to 4,500m (15,000 ft)
2.4.8. Power
Standard Input -48V DC
DC Input range -40.5 to 72V DC
Optional Input AC
2.4.9. Mechanical Dimensions
ODU
25 cm diameter x 20/23 cm depth
(10 diameter x 8 depth)
8.45 kg weight
IDU 4.3 cm height x 43.2 cm width x 24.0 cm depth
(1.7 x 17 x 9.4)
2.7 kg weight
IDU ODU Coaxial Cable RG-223 (100 m/300 ft), Belden 9914/RG-8 (300 m/1000 ft)
or equivalent, N-type connectors (male)