User's Manual Chapter 3

Chapter 3. Installation FibeAir 1500 Installation & Operation Manual
3-28 Installation Instructions Revision 2.0
1. Place U bolt (A) and safety collar (B) around the pole at the desired
height, connect them and tighten in place at a 90° angle to the opposing
site.
Place around pole
desired height
a
n
d
t
i
g
h
t
e
n
(A)
(B)
Safety collar
Ubolt
Figure 3-27 Antenna Assembly - Two Foot Antenna (cont.)
Note
The safety assembly installed above ((A) and (B)) is used to support the antenna mount
during installation and antenna alignment. Once the mount is in place and alignment is
completed, all bolted joints are tightened and there is no further need for the support
provided by the safety assembly. It may then be removed for use in future installations.