User's Manual Chapter 3

FibeAir 1500 Installation & Operation Manual Chapter 3. Installation
Revision 2.0 Installation Instructions 3-33
Figure 3-32 Attaching the ODU to the Mount Assembly
7. Connect the coaxial cable between the IDU and ODU using the N-Type
connectors on the IDU and the ODU.
Tip
Connect and disconnect the IDU from the ODU only when power is off.
8. Turn the power switch on the IDU to ON.
The LED display should appear as described below:
LED Color Explanation
PWR Green Power on
STBY Green Normal operation
BER Red Excessive bit errors detected
LINE Red No input to main channel/High BER
LBK Green Loopback not operated
LOF Red Loss of Frame detected (no radio connection)
IDU Green IDU operating and no IDU alarm
ODU Yellow Rx/Tx out of range
CBL Green Cable between ODU and IDU properly connected
RMT Red Remote unit not connected.
If the LED display is not as described above, refer to
Chapter 6 -
Troubleshooting & Diagnostics
.
9. Connect the headset BNC adapter to the ODU.
10. Connect the headset to the adapter and put it on.
Rubber
O-Ring