User's Manual Chapter 3

Chapter 3. Installation FibeAir 1500 Installation & Operation Manual
3-6 Installing the IDU - Rack Mount Assembly Revision 2.0
3.8. Installing the IDU - Rack Mount Assembly
The IDU may be installed in a 19" rack (1U) using the rack mount kit. The
mount braces are attached to each side of the IDU using the three holes on
each side. To attach the rack mount to the IDU follow these steps:
Figure 3-2 Rack Mount Assembly
1. Attach mount braces to each side of the IDU, and using the screws
supplied attach them to the holes in the IDU side panel (see illustration).
2. Install the IDU unit in the 19 rack as shown in the lower part of the
illustration.
3. To power on the unit, connect the WV-0001-0 cable supplied to the DC
Input interface on the front of the IDU and connect the other side of the
cable to the DC voltage supply:
White GND
Green +48v
Brown 0v
4. When more than one unit is installed, it is recommended to keep a gap
of 1U between the units in the rack.