Installation Instructions

CertainTeed Vinyl Siding Installation Guide
36
Product
Category
Max. Nail
Spacing Gaps to Accessories Overlap
Notes Specific
to Product
40°F
or Greater
Less
than
40° F
40°F
or Greater
Less
than
40° F
Cedar Impressions
Fasten
at Delta
Indicators
1/4" 3/8"
Use Temp.
Marks/
Gauge
Use Temp.
Marks/
Gauge
All panels must
be center pinned
(see page 95 for
more details)
Northwoods 16" 1/4" 3/8"
Use Temp.
Marks
Use Temp.
Marks
All panels must
be center pinned
(see page 125 for
more details)
CedarBoards 16" 1/4" 3/8"
1-1/2"
Butt Foam
1-1/2"
Butt
Foam
CedarBoards XL 16" 3/8" 1/2"
1-1/4" to
1-3/4"
1-1/2"
Butt
Foam
top most
nail at the
top of the
top most
full nail slot
center
remaining
nails in
the slot
3/8" to 1/2"
1/4" to 3/16"
Product
Category
Max. Nail
Spacing Gaps to Accessories
40°F
or Greater
Less
than
40° F
Vertical Siding 12"
3/16" top
3/8" bottom
1/4" top
1/2" bottom
Hang off of top nail slot (see page 80 for more details).