The required separation distances are measured from the actual location of the radiated part
of the antenna. An antenna may be inside the host application, affixed to the enclosure of the
host application or at the end of an optional extension coaxial cable.
Mobile applications:
Equipment must be mounted in a location at least 20cm away from areas likely to be
occupied by an unaware person.
Handheld applications:
All operators of handheld equipment with any type of antenna require training in the proper
operation of the equipment and such training must include RF exposure safety instructions.
Once training is completed they are considered to be aware persons.
If the portable operating pose is on the hand or arm it is required that a 5mm separation
between the radiating part of the antenna and nearby human tissue
If the portable operating pose is on the body it is required that a 15mm separation between
the radiating part of the antenna and nearby human tissue.
No safety warnings or precautions beyond normal operator training are required.
Required Training:
All installers and operators of host applications that include an SRF310 RT module must be
trained to use proper RF Safety precautions as presented in this section.