Installation manual
Table Of Contents
- FCC Statements
- Table of Contents
- List of Figures
- List of Tables
- Cervis Inc. Safety Precautions
- 2.0 TM70 System Description
- 3.0 CB70 Battery Charger and BT24IK Batteries
- 4.0 Receiver
- 5.0 Starting Up
- 6.0 Operating Instructions
- 7.0 Maintenance
- 8.0 Warranty
- 9.0 Parts Information
- 10.0 Programming a Spare Transmitter
- 11.0 Program the Machine ID in LCD Transmitters
- 12.0 Change Base Channel
- 13.0 CANopen Interface v2.4
- 14.0 LCD70 Display Option
- 15.0 First Come – First Served Operation
- 16.0 LA70 and LA70M Range Limiter
- 17.0 Tandem Operation
- 18.0 TM70 Analog Feedback Calibration
- 19.0 IN0450P Option
- 20.0 IN4D Option
- 21.0 INCAN Option
- 22.0 A1P4RCAN Option
- 23.0 A2ICAN Option
- 24.0 A2VCAN Option
- 25.0 Tele-Alignment Option
- 26.0 R70/Plus Receivers – Software V3.2 Compatible
- 27.0 i-Kontrol Console Box

TM70/3-10 & i-Kontrol Console RC System
U035.3-TM70_Console_Sys
4
2.1 TM70 System Specifications
Table 1. TM70 System Main Specifications
Transmitters: TM70/3, TM70/4, TM70/5, TM70/6, TM70/7, TM70/8, TM70/9, and TM70/10
Frequency band
914.150 – 915.875 MHz ERP < 1 mW
45.5 – 463.5 MHz ERP < 25 mW
Response Time
100 ms
Temperature Range
-4 to 158 °F (-20 to 70 °C)
Protection
IP65
Weight
Approximately 3 lbs.
Receivers: R70/13, R70/21, R70/29, R70/36, R70/13A4V, R70/13A6V, R70/13A8V,
R70/13A4I, R70/13A6I, R70/13A8I, and R70/Plus
Power Supply
48, 115, 230 VAC ± 10% -- 50/60 Hz
Optional 12 or 24 VDC
9 – 35 VDC (with external power supply)
Consumption
20 W
Relays
230 VAC/8A
STOP Relays
230 VAC/6A
Protection
IP65
Electrical Security
Class II (EN50178)
CB70 Battery Charger
Power Supply
115 VAC ±10% @ 50/60 Hz
12/24 VDC
BT24IK Batteries
Voltage
4.8 V
Capacity
2000 mAh NiMH
Charging Temperature
+32 to +113°F (0 to 45°C)
Discharge Temperature
-4 to 122°F (-20 to 50°C)
Battery Life
16 hrs. @ 50% duty cycle