Installation manual
Table Of Contents
- FCC Statements
- Table of Contents
- List of Figures
- List of Tables
- Cervis Inc. Safety Precautions
- 2.0 TM70 System Description
- 3.0 CB70 Battery Charger and BT24IK Batteries
- 4.0 Receiver
- 5.0 Starting Up
- 6.0 Operating Instructions
- 7.0 Maintenance
- 8.0 Warranty
- 9.0 Parts Information
- 10.0 Programming a Spare Transmitter
- 11.0 Program the Machine ID in LCD Transmitters
- 12.0 Change Base Channel
- 13.0 CANopen Interface v2.4
- 14.0 LCD70 Display Option
- 15.0 First Come – First Served Operation
- 16.0 LA70 and LA70M Range Limiter
- 17.0 Tandem Operation
- 18.0 TM70 Analog Feedback Calibration
- 19.0 IN0450P Option
- 20.0 IN4D Option
- 21.0 INCAN Option
- 22.0 A1P4RCAN Option
- 23.0 A2ICAN Option
- 24.0 A2VCAN Option
- 25.0 Tele-Alignment Option
- 26.0 R70/Plus Receivers – Software V3.2 Compatible
- 27.0 i-Kontrol Console Box

Operation and Installation Manual
2013 Cervis, Inc.
11
Table 3. Transmitter Details
Item Number
Indication
1
Crane Identification Label
2
LED
3
Command Controls
4
Contact Key
5
Start Button
6
STOP Button
7
Option: LA70 Range Limitation
8
Option: LCD70 Display and LA70 (able to be activated by EEPROM)
Figure 8. Transmitter Details
2. Turn the transmitter ON to OPERATION Mode as follows:
a. Place a charged battery in the transmitter.
b. Turn the Contact Key clockwise to ON.
c. Push in and then pull out the STOP Button. The transmitter LED flashes orange
once, and then illuminates green for three (3) seconds. If the transmitter has an
LCD, it displays the identification of the machine and the battery level.
d. Press and hold the START Button. The green LED should now light indicating
that the transmitter is transmitting. Release the START Button.
3. Upon receiving a signal from the transmitter, the receiver enters into Operation
Mode. The following LEDs will light up on the receiver:
Power ON – indicates that the power supply is OK.
HARDOK ON – indicates that board defects have not been detected.
1
2
3
4
5
7
8
6