Figure 12. CAN Bus LR72 PCB P4 Connection
13.3 Bus Termination
Adjacent to P4 is a jumper that can be configured to connect and disconnect bus termination.
Termination must be used on both ends of the bus connection, while all nodes between must not
be terminated. Specific details for terminating the network are included with Application Drawings
provided with your specific system.
13.4 Transmitter Data Dictionary
Table 8. Dictionary Items Supported by TM70
ID
Object
1000:
DEVICE TYPE
1001:
ERROR REGISTER
1002:
STATUS REGISTER
1003:
PREDEFINED ERROR FIELD