Installation manual
Table Of Contents
- FCC Statements
- Table of Contents
- List of Figures
- List of Tables
- Cervis Inc. Safety Precautions
- 2.0 TM70 System Description
- 3.0 CB70 Battery Charger and BT24IK Batteries
- 4.0 Receiver
- 5.0 Starting Up
- 6.0 Operating Instructions
- 7.0 Maintenance
- 8.0 Warranty
- 9.0 Parts Information
- 10.0 Programming a Spare Transmitter
- 11.0 Program the Machine ID in LCD Transmitters
- 12.0 Change Base Channel
- 13.0 CANopen Interface v2.4
- 14.0 LCD70 Display Option
- 15.0 First Come – First Served Operation
- 16.0 LA70 and LA70M Range Limiter
- 17.0 Tandem Operation
- 18.0 TM70 Analog Feedback Calibration
- 19.0 IN0450P Option
- 20.0 IN4D Option
- 21.0 INCAN Option
- 22.0 A1P4RCAN Option
- 23.0 A2ICAN Option
- 24.0 A2VCAN Option
- 25.0 Tele-Alignment Option
- 26.0 R70/Plus Receivers – Software V3.2 Compatible
- 27.0 i-Kontrol Console Box

TM70/3-10 & i-Kontrol Console RC System
U035.3-TM70_Console_Sys
30
13.8 TM70 CAN Receivers
Ref. 3302626 70GR902 RX-RCANNOCE Technical Specification
70GR902 RX-RCANNOCE Ref. 3302626
Specifications
Available frequencies (ISM bands)
915MHz (FCC certified)
Power supply / Maximum consumption
9-35v DC / 5W maximum
Inputs / Outputs interface
CAN: Standard CAN Open protocol 401 (CIA DS401)
Ingress protection
IP67 / NEMA-6
Antenna
External: NEARSON S325TR-015 or equivalent
Working frequency selection
Automatic: LBT (listen before talking)
Weight
430 gr.
Dimensions
Long = 151mm / Width = 129mm (160mm with PG) /
Height = 61mm
EEPROM
Extractable EP70 module
Signaling
Multiple LEDs:
7 external LEDS (6 green + 1 bicoloured)
2 internal LEDS (CAN status: 1 red + 1 green)
Connections
Fast PLUG-IN connectors and 2 x M16 cable glands
1) Power supply cable gland: M16 / IP67
2) Inputs / Outputs interface cable gland: M16 / IP67
STOP function
Cat. 1 EN-954-1 / 1 STOP relay: 250V / 6A maximum
STOP response time = 50 milliseconds
CAN BUS termination (120 Ohm)
ON / OFF jumper (internal)
Passive STOP time
Programmable: 0.5 to 2 seconds (max)
Input protection
PTC / 0,3A fuse
Output protections (STOP)
VDR in contacts
Operating mode temperature range
-20ºC / +70ºC (-4ºF / 158ºF)
Storage temperature (24h)
-25ºC / +75ºC (-13ºF / 167ºF)
Storage temperature –long periods-
-25ºC / +55ºC (-13ºF / 131ºF)
TM70 range supported transmitters
T70/1/2; T70/3/4; T70/5/6; T70/8