Installation manual
Table Of Contents
- FCC Statements
- Table of Contents
- List of Figures
- List of Tables
- Cervis Inc. Safety Precautions
- 2.0 TM70 System Description
- 3.0 CB70 Battery Charger and BT24IK Batteries
- 4.0 Receiver
- 5.0 Starting Up
- 6.0 Operating Instructions
- 7.0 Maintenance
- 8.0 Warranty
- 9.0 Parts Information
- 10.0 Programming a Spare Transmitter
- 11.0 Program the Machine ID in LCD Transmitters
- 12.0 Change Base Channel
- 13.0 CANopen Interface v2.4
- 14.0 LCD70 Display Option
- 15.0 First Come – First Served Operation
- 16.0 LA70 and LA70M Range Limiter
- 17.0 Tandem Operation
- 18.0 TM70 Analog Feedback Calibration
- 19.0 IN0450P Option
- 20.0 IN4D Option
- 21.0 INCAN Option
- 22.0 A1P4RCAN Option
- 23.0 A2ICAN Option
- 24.0 A2VCAN Option
- 25.0 Tele-Alignment Option
- 26.0 R70/Plus Receivers – Software V3.2 Compatible
- 27.0 i-Kontrol Console Box

TM70/3-10 & i-Kontrol Console RC System
U035.3-TM70_Console_Sys
38
14.6 Available Icons
Icons available for display are:
• Battery: 43h direction. This icon is composed by four other icons:
Battery cover
Left cell
Central cell
Right cell
• NEW: 2h direction. This will appear if the level is other than zero
14.7 VT100 Display Control
14.7.1 Control Characters
LDC70 recognized control characters are:
• ESC (1Bh): Control character that initializes a control sequence.
• NUL (00h): Ignored on input (not stored in the input buffer).
All other control characters cause no action to be taken
14.7.2 Valid Control Sequences
Definitions:
The following defines the basic elements of the ANSI mode control sequences.
1. VT100 Control Sequence Introducer (CSI): ESC [
2. Parameter string: A string of parameters separated by a semicolon (3Bh).
3. Final character: a character whose bit combination terminates an escape or control
sequence (‘m’, 6Dh).
Control Sequences
•
ESC [ 0 (1Bh 5Bh 30h): Control sequence to turn off all character attributes (‘0’ is the
optional, default value)
• ESC [Pn ; Pn H (1Bh 5Bh line 3Bh column 48h): moves the active position of the cursor to
the position specified by the parameters. The default condition with no parameters present
is equivalent to a cursor to home action. Lines are numbered consecutively, with the origin
being line 1, column 1. The cursor is not allowed to be positioned outside the margins
(lines 1 to 4, columns 1 to 12). A sequence with one Pn numeric parameter with a default
(0) parameter will be interpreted as wrong sequence. Example: ESC [ 2 ; 0 H or ESC [ 2 ;
H are wrong sequences!
• ESC [ 2 J (1Bh 5Bh 32h 4Ah): all lines are erased, and the cursor does not move
• ESC [ 4 (1Bh 5Bh 34h): All following characters transmitted are underscored until receiving
an escape sequence ESC [ 0 m
• ESC [ 5 (1Bh 5Bh 35h): All following characters transmitted are blink until receiving an
escape sequence ESC [ 0 m
• ESC [ 7 1Bh 5Bh 37h): All following characters transmitted are negative (reverse) image
until receiving an escape sequence ESC [ 0 m
All other control sequences or wrong sequences cause no action to be taken.
Example