Installation manual
Table Of Contents
- FCC Statements
- Table of Contents
- List of Figures
- List of Tables
- Cervis Inc. Safety Precautions
- 2.0 TM70 System Description
- 3.0 CB70 Battery Charger and BT24IK Batteries
- 4.0 Receiver
- 5.0 Starting Up
- 6.0 Operating Instructions
- 7.0 Maintenance
- 8.0 Warranty
- 9.0 Parts Information
- 10.0 Programming a Spare Transmitter
- 11.0 Program the Machine ID in LCD Transmitters
- 12.0 Change Base Channel
- 13.0 CANopen Interface v2.4
- 14.0 LCD70 Display Option
- 15.0 First Come – First Served Operation
- 16.0 LA70 and LA70M Range Limiter
- 17.0 Tandem Operation
- 18.0 TM70 Analog Feedback Calibration
- 19.0 IN0450P Option
- 20.0 IN4D Option
- 21.0 INCAN Option
- 22.0 A1P4RCAN Option
- 23.0 A2ICAN Option
- 24.0 A2VCAN Option
- 25.0 Tele-Alignment Option
- 26.0 R70/Plus Receivers – Software V3.2 Compatible
- 27.0 i-Kontrol Console Box

Operation and Installation Manual
2013 Cervis, Inc.
55
17.2 Two Master Transmitter Systems
Figure 32.Two Master Transmitters System
In Two Master Transmitter Systems, each transmitter will have a 1/1+2/2 Selector Switch and
an R (release) Pushbutton.
When Tandem Operation Is Needed (Figure 32)
In the following example, Master II is going to become the tandem operator for Receiver 1 and
Receiver 2.
1. Transmitter Master 1 operator must simultaneously press the R (release) and START
buttons. This frees Receiver 1.
2. Transmitter Master 2 operator sets the selector switch to 1 & 2.
3. Transmitter Master 2 operator presses and holds the START button until the Green LED
switches ON. This commands Receiver 2 to release Receiver 2, and then new ID codes are
sent to both Receiver 1 and Receiver 2.
Both receivers 1 and 2 are then started, ready for tandem operation.
When Tandem Operation Is Finished
When tandem operation has finished, the Master Transmitter must select Switch Position 2
again (in our example above) and press the Start button. Receiver 1 is release again ready to be
used by the Slave Transmitter to reconnect. The Master Transmitter then only controls Receiver
2.
Note: To reconnect Transmitter 1 to Receiver 1 in our example above, the operator must first
cycle the transmitter — power it OFF and then ON — and then press the START button while
the selector switch in set to 1.